Scaffold bracket TRG 80 and 120
A concreting scaffold is attached to
the TRIO formwork with scaffold
brackets 63. Fig. 46.
Allowed operating weight:
1.5 kN/m
2
. Scaffold Group 2
Decking and safety rails must attached
in such a way that they cannot tip or
bend.
Scaffolding parts provided by the
contractor must be in accordance
with the relevant safety regulations
(in Germany, DIN 4420).
– Timber parts must be of at least
Sort Class S10 according to
DIN 4074 and must be identified
(BGR 169).
– Cross-section of the safety planks:
3 cm x 15 cm.
– Secure boards.
With extended formwork units, the
scaffolding is assembled in the course
of the pre-assembly.
Fig. 46
63
Allowed load width in m for
wooden plank or board scaffold
decking
Table 8, DIN 4420 Part 1
B6 Working and
Concreting Scaffold
Scaffold Group Plank or board width
(cm)
Board or plank thickness (cm)
3.0 4.0
1, 2, 3 20
24 and 28
3.5 4.5 5.0
2.50
2.75
2.25
2.50
1.75
2.25
1.50
1.75
1.25
1.25